| Model | B140-12 |
|---|---|
| Capacity x Readability | 12 x 0.0005 lb 6 kg x 0.2 g |
| display resolution | 24,000 |
| Minimum Piece Weight | 0.0001 lb / 0.05 g |
| Display | Three six digit 14.2 mm / 0.56" high seven segment red LED display with three brightness levels |
| Operating Temperature | -10° C to 40° C / 14° F to 104° F |
| Power | Internal rechargeable battery giving 20 hours of use between charges. Recharge time approximately 8 hours. 12 volt UK/EU/ US power adaptor / recharger (supplied) with center positive. |
| Average Working Current | < 300mA |
| Battery | 6V4A/Hr rechargeable lead-acid battery |
| Auto off | Selectable between 1 and 30 minutes or off |
| Platform Material | Stainless steel |
| Pan Size | 11.5" W x 8.75" L x 0.5" H 292 mm (W) x 222 mm (L) x 13 mm (H) |
| Function Keys | On/Off; Clear; Enter; Zero; Tare; Total; kg/lb; Piece Weight; PLU; Print; |
| Annunciators | Zero; Tare; AC Mains Connected; Battery Charging; Stable; Big Bag; Small Bag; kg and lb |
| Scale Dimension | 11.5" W x 13.1" L x 4.3" H 292 mm (W) x 333 mm (L) x 109 mm (H) |
| Approvals | CE, UL and WEEE directive |
| Keyboard Functionality | 0-9– Used for keyboard entry of piece weight, sample size, and upper and lower limit settings |
| Units | Units used to switch displayed weights between kg and lb. |
| Zero | Return displayed weight and count to zero for accurate weighing and counting. Zero range capability is 5% of scale capacity |
| Enter/Pcwt | Enter used to confirm or save entered data from keyboard. Pcwt used for keyboard entry of a known average piece weight |
| Tare | Used to zero off (up to 100% of capacity) an empty container or weight, not required in the calculation of an average piece weight. Use of tare will reduce the scales maximum weight capacity by value stored |
| Total | Ability to add the display to an accumulator (Memory +) and only accumulate when there is a percentage of weight change |
| Clear/Hi/Lo | Clear to erase a keyed in value from the display if an error has been made. Hi/Lo is to set the upper and lower limits. |
| Upper | Used to set an upper limit quantity for count check feature |
| Lower | Used to set lower limit quantity for count check feature |
| On/Off | Used to turn off display for extended battery life or reset the scale to normal weighing mode |
| Output to RS-232 communications | |
| Packaging Dimension | 15" L x 18.5" W x 13.5" H 38.6 cm (L) x 21 cm (W) x 33.8 cm (H) |
| Shipping Weight | 4.5 kg / 10 lb |
| Model | B140-12 | B140-30 | B140-60 coin function |
|---|---|---|---|
| Capacity x Readability | 12 x 0.0005 lb 6 kg x 0.2 g |
30 x 0.001 lb 15 kg x 0.5 g |
60 x 0.002 30 kg x 1 g |
| display resolution | 24,000 | 30,000 | 30,000 |
| Minimum Piece Weight | 0.0001 lb / 0.05 g | 0.0002 lb / 0.1 g | 0.0005 lb / 0.2 g |
| Display | Three six digit 14.2 mm / 0.56" high seven segment red LED display with three brightness levels | ||
| Operating Temperature | -10° C to 40° C / 14° F to 104° F | ||
| Power | Internal rechargeable battery giving 20 hours of use between charges. Recharge time approximately 8 hours. 12 volt UK/EU/ US power adaptor / recharger (supplied) with center positive. | ||
| Average Working Current | < 300mA | ||
| Battery | 6V4A/Hr rechargeable lead-acid battery | ||
| Auto off | Selectable between 1 and 30 minutes or off | ||
| Platform Material | Stainless steel | ||
| Pan Size | 11.5" W x 8.75" L x 0.5" H 292 mm (W) x 222 mm (L) x 13 mm (H) |
||
| Function Keys | On/Off; Clear; Enter; Zero; Tare; Total; kg/lb; Piece Weight; PLU; Print; | ||
| - | Currency; Upper Limit; Lower Limit and 0 – 9 for data entry | ||
| Annunciators | Zero; Tare; AC Mains Connected; Battery Charging; Stable; Big Bag; Small Bag; kg and lb | ||
| Scale Dimension | 11.5" W x 13.1" L x 4.3" H 292 mm (W) x 333 mm (L) x 109 mm (H) |
||
| Approvals | CE, UL and WEEE directive | ||
| Keyboard Functionality | 0-9– Used for keyboard entry of piece weight, sample size, and upper and lower limit settings | ||
| Units | Units used to switch displayed weights between kg and lb. | ||
| Currency | - | Currency used to switch between currency type | |
| Zero | Return displayed weight and count to zero for accurate weighing and counting. Zero range capability is 5% of scale capacity | ||
| Enter/Pcwt | Enter used to confirm or save entered data from keyboard. Pcwt used for keyboard entry of a known average piece weight | ||
| Tare | Used to zero off (up to 100% of capacity) an empty container or weight, not required in the calculation of an average piece weight. Use of tare will reduce the scales maximum weight capacity by value stored | ||
| Total | Ability to add the display to an accumulator (Memory +) and only accumulate when there is a percentage of weight change | ||
| Clear/Hi/Lo | Clear to erase a keyed in value from the display if an error has been made. Hi/Lo is to set the upper and lower limits. | ||
| Upper | Used to set an upper limit quantity for count check feature | ||
| Lower | Used to set lower limit quantity for count check feature | ||
| On/Off | Used to turn off display for extended battery life or reset the scale to normal weighing mode | ||
| Output to RS-232 communications | |||
| Packaging Dimension | 15" L x 18.5" W x 13.5" H 38.6 cm (L) x 21 cm (W) x 33.8 cm (H) |
||