Seca mVSA 535 EMR-validated Spot-Check Vital Signs Monitor (NiBP, SpO2 Masimo, Rectal Temp)

Medical Equipment  >>   Blood Pressure Monitors  >>   Blood Pressure Monitors  >>   Seca  >>
Seca mVSA 535 EMR-validated Spot-Check Vital Signs Monitor (NiBP, SpO2 Masimo, Rectal Temp)

Discontinued

Free Shipping
(48 States)
Need Help? email us

Acquiring patient’s vitals is a routine task, performed on almost every patient. The seca mVSA 535 was designed to make this task as easy and efficient as possible. Staff at any level can operate the spot-check monitor due to its intuitive touch screen and self-explanatory user interface.

Features

Acquiring patient’s vitals is a routine task, performed on almost every patient. The seca mVSA 535 was designed to make this task as easy and efficient as possible. Staff at any level can operate the spot-check monitor due to its intuitive touch screen and self-explanatory user interface. The vitals capture is simple and fully validated for HL7 and many EMR systems. Connectivity to seca scales and measuring stations due to seca 360° proximity is also a plus as well as the unique seca EQ BP™ technology. The seca mVSA fits perfectly into your existing workflows and frees up time and resources to improve patient care.

Product Properties
  • Easy to operate spot-check monitor to capture all basic routine patient vitals in less than 60 seconds
  • Quick and accurate blood pressure measurement in under 20 seconds
  • Configurable seca EQ BP™ average mode (BP30) provides true screening of hypertension
  • seca scale connectivity through seca 360° proximity: One integration interface for all seca devices
  • World-class service program with no downtime
  • Long lasting battery for up to 150 measurements on one single charge
  • Convincing data storage: All measurements stored and available for later processing
  • EMR-validated: transmit measured data directly to any electronic medical record system or printer
Key-Technical Data
  • Blood pressure measurement method: Oscillometric, deflation or inflation measurement
  • Blood pressure measurement time: Normal: 15 - 20 sec / max. 90 sec (adults)
  • SpO2 measurement: methodPulse oximetry
  • Temperature measurement response time: Predictive (oral) 3 - 10 sec.; Predictive (axillary/rectal) 8 - 14 sec.; Direct 60 - 120 sec
  • Temperature measuring method: Rectal (direct or predictive)

Specifications

Model 5351010131 5351020131 5351200131 5351210131 5351220131
Main Functions NiBP, Oral Temp NiBP, Rectal Temp NiBP, SpO2 Masimo NiBP, SpO2 Masimo, Oral Temp NiBP, SpO2 Masimo, Rectal Temp
Display 7" Touchscreen-Display
BIA module Without BIA Module
Blood pressure measurement range – deflation pSYS: 25 - 280 mmHg pDIA: 10 - 220
mmHg pMAP: 15 - 260 mmHg
Blood pressure measurement range – inflation pSYS: 77 - 200 mmHg pDIA: 45 - 190
mmHg pMAP: 56 - 193 mmHg
Blood pressure measurement accuracy – deflation (clinical validated) Mean deviation systole 0.39 mmHg; Standard deviation systole 2.57 mmHg;
Mean deviation diastole 0.43 mmHg; Standard deviation diastole 1.73 mmHg
Blood pressure measurement accuracy – inflation (clinical validated) Mean deviation systole 0.94 mmHg; Standard deviation systole 3.84 mmHg;
Mean deviation diastole 0.57 mmHg; Standard deviation diastole 3.17 mmHg
Blood pressure measurement method Oscillometric, deflation or inflation measurement
Blood pressure measurement certainty Excess pressure limit 300 mmHg;
automatic pressure release at > 300 mmHg
Blood pressure measurement time Normal: 15 - 20 sec / max. 90 sec (adults)
Blood pressure pulse rate accuracy max. +/- 3 bpm
Blood pressure pulse rate range – deflation 30 - 240 bpm
Blood pressure pulse rate range – inflation 45 - 200 bpm
Net weight 5.9 lbs / 2.7 kg
Product height 10.3 inch / 262 mm
Product width 10.0 inch / 254 mm
Product depth 10.9 inch / 278 mm
Ports Ethernet
USB 2.0
Wi-Fi
SpO2 module Without SpO2 module Masimo SpO2 module
SpO2 measurement range 0 - 100 %
SpO2 measurement accuracy SpO2 (resting) 70 % - 100 % ± 2
Arms; SpO2 (in motion) 70 % - 100 % ± 3 Arms
SpO2 measurement method Pulse oximetry
SpO2 pulse rate measurement range Pulse rate: 25 bpm to 240 bpm
Perfusion index measuring range 0.02% - 20.0%
SpO2 pulse rate measurement accuracy PR (no motion) 25 - 240 bpm ± 3 digits
PR (in motion) 25 - 240 bpm ± 5 digits
Power supply Built-in power adapter
internal rechargeable lithium-ion battery
Temperature measuring range Direct 30 °C - 43 °C (86 °F - 109.4 °F
predictiv 35.5 °C - 42 °C (95.9 °F - 107.6 °F)
- Direct 30 °C - 43 °C (86 °F - 109.4 °F
predictiv 35.5 °C - 42 °C (95.9 °F - 107.6 °F)
Temperature measurement response time Predictive (oral) 3 - 10 sec Predictive (axillary/rectal) 8 - 14 sec.
Direct 60 - 120 sec
- Predictive (oral) 3 - 10 sec Predictive (axillary/rectal) 8 - 14 sec.
Direct 60 - 120 sec
Temperature measurement accuracy Direct ± 0.1 °C (± 0.2 °F)
Predictive (for 95 % of measurements) ± 0.1 °C (± 0.2 °F)
- Direct ± 0.1 °C (± 0.2 °F)
Predictive (for 95 % of measurements) ± 0.1 °C (± 0.2 °F)
Temperature measuring method Oral/axillary (direct or predictive) axillary/rectal (direct or predictive) - Oral/axillary (direct or predictive) axillary/rectal (direct or predictive)
Temperature module Filac™ temperature oral/axillary Filac™ temperature axillary/rectal - Filac™ temperature oral/axillary Filac™ temperature axillary/rectal