METTLER TOLEDO NineFocus pH Sensor InLab Micro Pro-DES - 31027062
A combination pH electrode with a ceramic junction and narrow sensing membrane for small sample volumes or for measuring in small containers, as part of our Diagnosable, Efficient, and Sustainable InLab DES digital electrode line. Designed for use in a variety of applications.
Ideal for critical samples where there is low sample volume or in small containers such as vials and test tubes. Mettler Toledo Micro Series pH and pH/ATC Combination Electrodes with ceramic junction allows for accurate measurements no matter the sample volume.
| Model | 31027061 Expert |
31027062 Micro |
31027063 Solids |
31027064 Science |
31027065 Max |
31027066 Pure |
31027067 Ultra Micro |
|---|---|---|---|---|---|---|---|
| pH range | 0 – 14 | 0 – 14 | 1 – 11 | 0 – 12 | 0 – 14 | 1 – 11 | 1 – 11 |
| Temperature range | 0 to 100 oC | 0 to 100 oC | 0 to 80 oC | 0 to 100 oC | 0 to 100 oC | 0 to 80 oC | 0 to 80 oC |
| Type of junction | 2 open junctions | Ceramic | Open junction | Moveable glass sleeve | Immoveable glass sleeve | Immoveable glass sleeve | Ceramic |
| Shaft Material | PEEK | Glass | Glass | Glass | Glass | Glass | Glass |
| Sensor type | Combined electrode | Combined electrode | Combined electrode | Combined electrode | Combined electrode | Combined electrode | Combined electrode |
| Shaft length | 120 mm | 130 mm | 25 mm | 170 mm | 120 mm | 170 mm | 40 mm |
| Shaft Diameter | 12 mm | 5 mm | 6 mm | 12 mm | 12 mm | 12 mm | 3 mm |
| Parameter | pH | pH | pH | pH | pH | pH | pH |
| Reference System | ARGENTHAL™ with Ag+-trap | ARGENTHAL™ with Ag+-trap | ARGENTHAL™ with Ag+-trap | ARGENTHAL™ with Ag+-trap | ARGENTHAL™ with Ag+-trap | ARGENTHAL™ with Ag+-trap | ARGENTHAL™ with Ag+-trap |
| Reference electrolyte | XEROLYT® Polymer | 3 mol/L KCl | XEROLYT® EXTRA Polymer | 3 mol/L KCl | 3 mol/L KCl | 1 mol/L KCl,3 mol/L KCl | FRISCOLYT-B® |
| Membrane glass | U | U | LoT | A41 | HA | LoT | LoT |
| Membrane resistance (25°C) | < 250 mΩ | < 300 mΩ | < 250 mΩ | < 600 mΩ | < 600 mΩ | < 50 mΩ | < 700 mΩ |
| Minimum sample volume | 20 mL | 100 µL | 20 mL | 20 mL | 20 mL | 20 mL | 15 µL |
| Temperature probe | NTC 30 kΩ | NTC 30 kΩ | NTC 30 kΩ | NTC 30 kΩ | NTC 30 kΩ | NTC 30 kΩ | No |
| Low Maintenance | YES | No | YES | No | No | No | No |
| Signal type | Digital | Digital | Digital | Digital | Digital | Digital | Digital |
| Reference electrolyte Order no. | - | 51343180 | - | 51343180 | 51343180 | 51343180 | 51343180 |
| Application Notes | Fruit Juice,Rice | TRIS-Containing Samples,Small-Volume Samples | Plant-Based Proteins, Brine, Cream, Seafood, Cheese, Yogurt, Meat, Jam and Jelly, Fruits and Vegetables, Sauce, Canned Foods, Sushi Rice, Milk,Rice | Organic Solvents,Silver Nitrate,e-Liquids,Protein-Containing Samples,TRIS-Containing Samples,Hand Sanitizer,Paints | Wine,Liquid Culture Media,Cathode Materials,Fruit Juice,Pharmaceutical Suspensions,Soft Drinks,Protein-Containing Samples,Sauce,Brine,Hand Sanitizer,Paints,Beer | Pure Water,Surfactant | Small-Volume Samples |
| Cable included | No | No | No | No | No | No | No |
| Compatible Meter | NineFocus | NineFocus | NineFocus | NineFocus | NineFocus | NineFocus | NineFocus |
| Connector on Sensor | To Signal Bridge (sVP8) | To Signal Bridge (sVP8) | To Signal Bridge (sVP8) | To Signal Bridge (sVP8) | To Signal Bridge (sVP8) | To Signal Bridge (sVP8) | To Signal Bridge (sVP8) |
| DES® - Sensor Diagnostics | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Links to Application Notes | rice, fruit-juice | small-samples, TRIS-samples | brine, fruits-and-vegetables, yogurt, rice, sauce, milk, plant-based-proteins, sushi-rice, seafood, cream, meat, cheese, canned-foods, jam-and-jelly | eliquids, Protein-samples, hand-sanitizer, paints, silver-nitrate, TRIS-samples, organic-solvents | wine, brine, Protein-samples, hand-sanitizer, liquid-culture-media, sauce, cathode-material, paints, beer, suspensions, soft-drinks, fruit-juice | pure-water, surfactants | small-samples |
| Recommended Meter Models | NF2300,NF2000,NF2340 | NF2300,NF2000,NF2340 | NF2300,NF2000,NF2340 | NF2300,NF2000,NF2340 | NF2300,NF2000,NF2340 | NF2300,NF2000,NF2340 | NF2300,NF2000,NF2340 |
| Recommended Meters | NineFocus | NineFocus | NineFocus | NineFocus | NineFocus | NineFocus | NineFocus |
| Sample Composition | Aqueous | Aqueous | Solids/semi-solids | Non-Aqueous | Aqueous,Contains proteins/TRIS/sulphides (aqueous) | Low ionic strength (aqueous) | |
| Sample Consistency | Liquid,Sludge/slurry/suspension | Aqueous,Contains proteins/TRIS/sulphides (aqueous),High salt content (aqueous) | Solid/semi-solid (measure inside sample/puncture) | Liquid | Liquid,Sludge/slurry/suspension | Liquid | Aqueous,Contains proteins/TRIS/sulphides (aqueous),High salt content (aqueous) |
| Sample temperature | 0°-100°C | 0°-100°C | 0°-100°C | 0°-100°C | 0°-100°C | 0°-100°C | 0°-100°C |
| Sample Volume | >= 20 ml | 100 µl - 500 µl | >= 20 ml | >= 20 ml | >= 20 ml | >= 20 ml | < 100 µl |
| Sensor characteristics | Automatic Sensor Recognition,Temperature probe,Calibration History Stored,Mechanically robust | Automatic Sensor Recognition,Chemically robust,Temperature probe,Calibration History Stored,Small volume | Automatic Sensor Recognition,Chemically robust,Temperature probe,Calibration History Stored | Automatic Sensor Recognition,Chemically robust,Temperature probe,Calibration History Stored | Automatic Sensor Recognition,Chemically robust,Temperature probe,Calibration History Stored | Automatic Sensor Recognition,Chemically robust,Temperature probe,Calibration History Stored | Automatic Sensor Recognition,Chemically robust,Calibration History Stored,Small volume |
| Typical Samples | Water,Beer, Suspended soil | TRIS buffers,Enzyme solution,Proteinaceous samples | Fruit & Vegetables,Cheese,Meat & Fish | Organic solvents,Petrol,Alcohols | Liquid Culture Media, Wine, TRIS buffers | Distilled water,Water for injection,Sterile water | TRIS buffers,Enzyme solution,Proteinaceous samples |
| Unique Sensor Purpose | Generalist Best Choice | Small Volumes (100 µL - 20 mL) | Solids/Semi-solids | Organic Solvents | pH < 2 and > 12 | Pure Water | Very Small Volumes (15 - 100 µL) |